• of8
#2 Phillips HeadScrewdriver5/32" Drill Bit 11/32" Drill Bit 1/8" Drill Bit2. Tools RequiredLever Release Tool(Included)Installation InstructionsCLX3300 Series Cylindrical LocksetWARNINGThis product can expose you to lead which is known to the state ofCalifornia to cause cancer and birth defects or other reproductiveharm. For more information go to www.P65warnings.ca.gov.FM566-EN 12/25For installation assistance contact Corbin Russwin1-800-543-3658 • techsupport.corbinrusswin@assaabloy.comCopyright © 2021-2025, ASSA ABLOY Access and Egress Hardware Group, Inc. All rights reserved. Reproduction in whole or inpart without the express written permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.Attention Installer: Improper installation may result indamage to the product and void the factory warranty.WARNING1. Part IdentificationFig. Description1 Inside lever handle2 Rose/Scalp (2)3 Screws - latch (2) #8-32 x 3/4"4 Inside spring housing assembly5 Screws - through-bolt (2) #12-24 x1-1/2"6 Lockbody assembly with rose liner7 Outside spring housing assembly8 Cylinder spacer9 Cylinder10 Outside lever handle11 Key12 Lever release tool13 Latch14 Screws - strike (2) #12-24 x 1"15 Strike16 Strike box (Optional)12625789101112153 4131416
4. Latch InstallationStrike2CLX3300 SeriesCylindrical LocksetFM566-EN 12/25For installation assistance contact Corbin Russwin1-800-543-3658 • techsupport.corbinrusswin@assaabloy.comCopyright © 2021-2025, ASSA ABLOY Access and Egress Hardware Group, Inc. All rightsreserved. Reproduction in whole or in part without the express written permission ofASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.3. Door PreparationIMPORTANT The accuracy of door preparation is critical for proper functioning and security of this lever handle lock. Misalignment cancause premature wear and a lessening of security. Verify backset before marking and drilling door.1. Use template FM567 to mark the door. See Figure 1.2. Drill the door according to the template.4. Install the strike. See Figure 3.DOORFRAMEDesiredheightabovefloorTemplateBackset mustmatch latchDoor bevelFigure 13. Verify the dimensions. See Figure 2.Figure 2 Figure 311/32" (8.7mm) hole2-1/8"(54mm)hole1-1/8"(29mm)2-1/4"(57mm)1" (25mm)hole5/32" (4mm)2-3/4"(70mm)Strike BoxAttaching ScrewsStrike BoxAttaching Screws#8 -32 x 3/4"#12 -24 x 1"1. Insert latch in door. Bevel edge of bolt must face the strike plate2. Attach with (2) #8-32 x 3/4" screws supplied.
5. Adjust Lock for Door Thickness (if necessary)Lock is factory preset for 1-3/4" (44mm) doors unless specified. To adjust lock to door thickness if other than 1-3/4" (44mm):1. Remove outside trim assembly from the lockbody assembly. The lever, rose, and spring housing will remove as one piecefrom the lockbody (See Figure 4).2. Rotate outside rose liner to adjust lock to fit door thickness, so distance (Dimension A) from inside surface of liner tocenterline of retractor is half the thickness of the door (See chart and Figure 5).3. Reassemble outside trim assembly onto lockbody assembly.Door Thickness Dimension A1-3/4" (44 mm) 7/8" (22 mm)2" (50 mm) 1" (25 mm)2-1/4" (57 mm) 1-1/8" (29 mm)Outside Rose LinerOutsideTrimAssemblyLockbodyAssembly1. Insert outside trim assembly into door fromoutside making sure that lockbody hooks latchcase and retractor engages bolt tail(s) (SeeFigure 6).DO NOT FORCE. (If lockbody does not engage latcheasily, check door preparation for errors.)Latch bolt tail should be centered in depth ofretractor. If it is not, refer to Section 5 to properlyadjust the lock for door thickness.6. Install Outside AssemblyTo adjust lock to door thickness if other than 1-3/4" (44mm) refer to Section 5.3CLX3300 SeriesFor installation assistance contact Corbin Russwin1-800-543-3658 • techsupport.corbinrusswin@assaabloy.comCopyright © 2021-2025, ASSA ABLOY Access and Egress Hardware Group, Inc. All rightsreserved. Reproduction in whole or in part without the express written permission ofASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.FM566-EN 12/25Cylindrical LocksetFigure 4Centerline of RetractorRetractorDimension AFigure 5Figure 6
7. Install Inside Components8. Cylinder Installation (If units provide less cylinder or with construction cores)a. Fixed Core Cylinder (Figure 9)1. Remove temporary construction core or plastic core. If keyed,use Control Key. Rotate 15° and pull.2. Insert permanent core into lever with control key. Rotate 15°and remove key..KeyOutside LeverCylinderCylinder SpacerIMPORTANT Before installing cylinders: Use a flat blade screwdriver to rotate cam until the driver points arein a 6 and 12 o’clock position (See Figure 15 on next page). Timing may need adjusting on certain functions. See Section 10 LockTiming on pages 5 and 6.Correct Key Orientation During AssemblyVerify that the cylinder spacer is already installed into the shank on the outsidespring housing assembly. Cylinder spacer should be removed for 7-Pin cylinder.Note orientation of spacer, if it needs to be reinstalled.b. Interchangeable Core LFIC or SFIC (Figure 10)4CLX3300 SeriesCylindrical LocksetFM566-EN 12/25For installation assistance contact Corbin Russwin1-800-543-3658 • techsupport.corbinrusswin@assaabloy.comCopyright © 2021-2025, ASSA ABLOY Access and Egress Hardware Group, Inc. All rightsreserved. Reproduction in whole or in part without the express written permission ofASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.Figure 71. Remove lever and rose from inside spring housing assembly.2. Align and insert inside spring housing onto the installed lockbody.3. Install screws to tighten the lock to the door.4. Orient dimples on side of rose with openings on side of spring housing assembly (See Figure 7).5. Install rose onto the inside spring housing assembly.6. In the unlocked position, verify the button is adjusted properly. See Figure 8 for proper alignment. Adjust if necessary.7. Install inside lever.Note: Test for proper operation before closing door. Button in-line with shankindicates correct position basedupon door thickness. If thebutton needs to be adjusted,position it by depressing theplunger, moving it in or out asneeded.ShankPlungerScrews (2) #12-24 x 1-1/2"Rose dimpleRose dimple openingFigure 8Figure 9Figure 10CCNew Core
9. Lever Removal and Installationa. Standard Cylinder (Figure 11)To Remove:Rotate key 45° and hold. Depress lever catch with lever release tool.Lever catchTo Remove:Remove core and tailpiece, using key marked “control.”Insert slotted screwdriver or lever release tool into cylinder opening and makecontact with lever catch.Pull lever catch horizontally towards the opposite side of the cylinder openingand remove lever.To Install:Without the core installed, slide the lever on over the lever catch. Confirm thelever will not pull off. Install core and tailpiece, using key marked “control.”To Remove:Depress lever catch with lever release tool, removelever.To Install:Slide the lever on over the lever catch. Confirm thelever will not pull off.Control KeyTo Install:With driver points at 6 and 12 (See Figure 15), rotate key 45° ineither direction and slide lever on over the lever catch. Confirm thelever will not pull off.1. Remove cylinder lever(s) to view internal cam (See Figure 15).2. Adjust internal cam on each side that has a cylinder. To adjust:a. Use a slotted screwdriver to rotate cam fully clockwise.b. Rotate cam back until driver points are at the 6 and 12 o’clockposition.3. Re-install levers with cylinders (See Section 9a).4. Test cylinder(s) with key before closing door.5. Confirm outside key rotates approximately 180° in both directions.6. If outside key rotates 360°, repeat steps 1-5.View into lock from end of trim12 o’clock drive point6 o’clock drive pointInternal camTiming is required if cylinders were not provided factory installed. See page 8 for CLX3329 hotel function.b. Interchangable Core LFIC or SFIC (Figure 12)c. Plain Lever (Figure 13) & Push/Turn Button (Figure 14)10. Lock Timinga. Functions CLX3352, CLX3355, & CLX33825CLX3300 SeriesFor installation assistance contact Corbin Russwin1-800-543-3658 • techsupport.corbinrusswin@assaabloy.comCopyright © 2021-2025, ASSA ABLOY Access and Egress Hardware Group, Inc. All rightsreserved. Reproduction in whole or in part without the express written permission ofASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.FM566-EN 12/25Cylindrical LocksetFigure 11Figure 12Figure 14Figure 13Figure 15