Search Search Match Case Whole words Index View mode Thumbnails Download Print Fullscreen Share Crop Snip Navigation Selection mode Close PDF * Page of4 * * 100% * * * * FM635 03/23 Installation Instructions CLX3300 Series Electrified Cylindrical Lockset WARNING This product can expose you to lead which is known to the state of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65warnings.ca.gov. Attention Installer: Improper installation may result in damage to the product and void the factory warranty. WARNING For installation assistance contact Corbin Russwin 1-800-543-3658 • techsupport.corbinrusswin@assaabloy.com Copyright © 2022-2023, ASSA ABLOY Access and Egress Hardware Group, Inc. All rights reserved. Reproduction in whole or in part without the express written permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited. Installation Notes1 • Doors manufactured by ASSA ABLOY Group Companies are available pre-wired with ElectroLynx® connectors. • Wire colors are consistent with all ASSA ABLOY products. • Doors without ElectroLynx connectors will have to be hard wired. • For Non ElectroLynx Connector System Door: » Install available Retrofit Harness and use with ElectroLynx Hinge. » Follow installation instructions for ElectroLynx Connector System. • For Non ElectroLynx Connector System Door and Hinge: » Remove connector on lock. » Use proper crimp splices or wire nuts in accordance with local code for terminating connections. » Lock is polarity sensitive. • The system shall not be installed in fail secure mode unless permitted by the local authority having jurisdiction and shall not interfere with the operation of Listed panic hardware. • Power shall be by UL294 and ULC-60839 Class 2 Power Limited power supplies or Listed Access Control units. • ULC-60839-11-1 - Grade 1 and Environmental class: indoor only. • UL294 access control performance levels (Endurance Level IV, Line Security Level I, Attack Level I, Power Stand- by Level I). • Wiring methods shall be in accordance with the National Electrical Code (ANSI/NFPA70), CSA 22.1, Canadian Electrical Code (CEC), Part I, Safety Standard for Electrical Installations, local codes and the authorities having jurisdiction. Electrical Specifications2 • Operating voltage range: 10.2VDC to 26.4VDC • Current draw: 10mA continuous. • Peak current draw: 500mA. Total One-Way Length of Wire Run (ft) 12VDC Load Current @ 12VDC 24 VDC Load Current @ 24VDC 1/2A 1A 1/2A 1A 100 18 14 20 18 150 16 12 18 16 200 14 12 18 14 250 14 10 16 14 Wire Gauge Chart Note: The minimum permissible wire size to be used shall not be less than 26 AWG. When calculating voltage drop, use 0.5A as the recommended current draw. 2FM635 03/23 CLX3300 Series Installation InstructionsElectrified Cylindrical Lockset For installation assistance contact Corbin Russwin 1-800-543-3658 • techsupport.corbinrusswin@assaabloy.com Copyright © 2022-2023, ASSA ABLOY Access and Egress Hardware Group, Inc. All rights reserved. Reproduction in whole or in part without the express written permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited. Verify / Configure Lock for Fail Safe or Fail Secure4 Locks are configurable for Fail Safe or Fail Secure applications, locate dip switch as shown below. Dip switch can only be accessed prior to lock installation. • Power cycling is required after changing switch position. Door Preparation3 Refer to Template T30971 (and also T31261 if BHSS trim) for door preparation. Use door marker provided with lock to verify dimensions. Figure 1 DIP Switch for Fail Safe or Fail Secure FAIL SECURE FAIL SAFE MOVE THE DIP SWITCH TO THE POSITION DESIRED. POWER CYCLE AFTER CHANGING SWITCH POSITION. 3FM635 03/23 F or installation assistance contact Corbin Russwin 1-800-543-3658 • techsupport.corbinrusswin@assaabloy.com Copyright © 2022-2023, ASSA ABLOY Access and Egress Hardware Group, Inc. All rights reserved. Reproduction in whole or in part without the express written permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited. CLX3300 Series Installation InstructionsElectrified Cylindrical Lockset Installation5 Install lock per instruction sheet FM566 (or FM589 if BHSS trim), provided with lock. See Figure 2. 1. Plug the 8-pin connector from the lock into the 8-pin connector for the wiring harness thru the door. 2. Plug the 8-pin connector from the door harness into the 8-pin hinge connector. 3. Connect the hinge connector to the transformer or power supply. Caution: Verify that the correct voltage and polarity is being used. The voltage must not exceed 30VDC. If voltage exceeds this value, the lock may be damaged. Lock is polarity sensitive. 4. Test lock • Fail Secure – applying power unlocks • Fail Safe – applying power locks Note: Typical door harness location is shown. Other locations may exist depending on door type. Door harness with 8- and 4-pin connectors. 4-pin connector is not used. 8- wire QC8 Electric Hinge with 8-pin connector Pigtail Harness (QC2 shown) 2-wire with 8-pin connector Lock with 8-pin connector. Lock polarity is sensitive. Red (+), 2 Black (-), 1 Black (-) Red (+) Blue Yellow Green Orange White Brown To transformer or power supply Red, 2 Black, 1 1 3 2 Figure 2 FM635 03/23 For installation assistance contact Corbin Russwin 1-800-543-3658 • techsupport.corbinrusswin@assaabloy.com Copyright © 2022-2023, ASSA ABLOY Access and Egress Hardware Group, Inc. All rights reserved. Reproduction in whole or in part without the express written permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.L N 120VAC 60HZ + -+ - Output 1 Output 2 120VAC L/N/G GND Plug into 8-pin hinge connector at door Pigtail Harness (QC2 shown) 2-wire with 8-pin connector Red (+), 2 Black (-), 1 NC NO Switch or relay contacts C Normally Closed Fire Alarm Contact (if required) 12VDC or 24VDC Regulated and Filtered Power Supply Input (+) PIN 2 RED RX SWITCHC NC NO 8 5 7 2 4 6 1 3 PIN 3 WHITEPIN 4 GREENPIN 5 ORANGE (-) PIN 1 BLACK 12/24VDC Input Power NOTE: RX SWITCH MONITORS INSIDE HANDLE Wiring Diagram6 Request to Exit Switch Wiring Diagram7 Figure 3 Figure 4 Assa Abloy Privacy Preference Center When you visit any website, it may store or retrieve information on your browser, mostly in the form of cookies. This information might be about you, your preferences or your device and is mostly used to make the site work as you expect it to. The information does not usually directly identify you, but it can give you a more personalized web experience. Because we respect your right to privacy, you can choose not to allow some types of cookies. Click on the different category headings to find out more and change our default settings. However, blocking some types of cookies may impact your experience of the site and the services we are able to offer. Allow All Manage Consent Preferences Essential Always Active These cookies are necessary for the website to function and cannot be switched off in our systems. They are usually only set in response to actions made by you which amount to a request for services, such as setting your privacy preferences, logging in or filling in forms. You can set your browser to block or alert you about these cookies, but some parts of the site will not then work. These cookies do not store any personally identifiable information. Functional Functional These cookies enable the website to provide enhanced functionality and personalisation. They may be set by us or by third party providers whose services we have added to our pages. If you do not allow these cookies then some or all of these services may not function properly. Performance Performance These cookies allow us to count visits and traffic sources so we can measure and improve the performance of our site. They help us to know which pages are the most and least popular and see how visitors move around the site. All information these cookies collect is aggregated and therefore anonymous. If you do not allow these cookies we will not know when you have visited our site, and will not be able to monitor its performance. Marketing Marketing These cookies may be set through our site by our advertising partners. They may be used by those companies to build a profile of your interests and show you relevant adverts on other sites. They do not store directly personal information, but are based on uniquely identifying your browser and internet device. If you do not allow these cookies, you will experience less targeted advertising. Back Button Cookie List Search Icon Filter Icon Clear checkbox label label Apply Cancel Consent Leg.Interest checkbox label label checkbox label label checkbox label label Reject All Confirm My Choices Powered by Onetrust