*Actual product and finish may vary
782 Yale/Corbin-Russwin Controller is required for electric latch retraction and is designed to control one or two electric latch retraction “P” exit devices.
Equipped with two 20-second timers which can operate the exit devices together or independently.
Requires a momentary or timed, dry contact input and can be interfaced with access control systems, automatic door operators, “blow open” type scenarios and has provisions for N/C fire alarm systems.
Note: The 782 is required for use with the “P” latch retraction option.
Using any other power supply with the “P” option voids the warranty of the device.
Features
• 2 control inputs. Accepts normally closed dry contacts for device activation from a key switch, push button, access control or fire alarm system.
• 2 normally open control outputs for automatic door operators
• 2 “P” device outputs
• Fire Alarm Interface input
• 24VDC output for audible or LEDS .25 AMP
Electrical Specifications
• 120VAC 60 Hz 750mA (max)
• 10 amp inrush
Listings
UL 294
UL CLASS 2 outputs
Applications
“P” Electric Latch Retraction Option
Up to 60 feet: 14 AWG wire
Up to 100 feet: 12 AWG wire