*Actual product and finish may vary
Norton 5710 Door Operator Low Energy Pull Side mounting Rigid Arm and Slide Track
Electrical Data
Power Input; 120 VAC, 60Hz
Current Draw:;0.9A
Auxiliary Output: 24VDC @ 1.1A
Relay Output: 0.9A
Normally Open/Normally Closed (jumper) for electric strike function
C-UL US listed for use on fire and smoke barrier doors
Meets ADA requirements
ANSI/BHMA A156.19 certified
Meets ANSI/BHMA A156.4 requirements
2-year limited warranty
Features
Ease of installation and setup
Simple instructions
Application versatility and ease of adjustment; push or pull side mounting units available
Operates
as mechanical surface closer during close cycles, when door is opened
manually or if power is turned off; quiet operation
Spring force provides the feel of a normal manual door closer; door can be opened manually if desired.
Functions
Norton® 1601/1601BF series door closer
Non-Handed
Unit Activation Options: wall switches, motion sensor, radio frequency device
End-User On/Off Switch
Hold Open options; 0-30 seconds (5 seconds minimum required for ADA and ANSI/BHMA A156.19)
Obstruction Detection: motor stops if door is obstructed during an opening; door closes under manual spring force (not to exceed 15lbf)
"Push and Close"; allows the operator to skip the hold open time when it is not necessary or required
Adjustable door sensitivity
Overload Safety Shut-Off - after two minutes of receiving a door activation signal, the inverter will time out and close the door; prevents motor/inverter damage
Motor Start Delay for Locking Hardware - 0-5 second delay to allow locking hardware to release first
Onboard power supply for accessories: 24VDC (1.1A)
Specifications
Door Controls (interior) (exterior) swinging door(s) shall be of
rack and pinion design contained within a precision cast aluminum
housing. Door closing force shall be adjustable to ensure adequate
closing control. Door closing speed shall be controlled by independent
hydraulic adjustment valves in the sweep and latch range of the closing
cycle. Door Operator shall provide conventional door closer opening
forces unless the power operator motor is activated. Door Operator shall
provide conventional door closing forces at all times except in the
event of power outage during powered door open cycle. Door Operator
opening force and speed shall be adjustable by independent electronic
adjustment to ensure adequate opening control per accessibility codes.
Door Operator shall have an adjustable hydraulic backcheck valve to
cushion the door speed if door is opened violently. Door Operator shall
have a manual adjustment to locate both full open and full closed door
positions. Maximum door open shall be adjustable and capable to a
maximum 180° conditions permitting. [(Door Operator shall be SELECTIVELY
ACTIVATED by external initiating device, i.e., wall switch, etc.)] Door
operator shall have adjustable hold open time capability in range from 5
to
30 seconds. Door operator shall have input line rating of
120VAC, .6A or 240VAC, .3A. Units shall have relay contact for
interfacing products having a contact rating of 30VDC at 1A or 125VAC at
.5A. Unit shall have an external On/Off Switch to defeat powered
opening when desired. Unit shall have an internal circuit breaker switch
to interrupt input power for servicing. Unit shall be U.L. Listed for
automatic closing door. Unit shall be in compliance with the
requirements of the Americans With Disabilities Act (ADA), ANSI
standards A117.1 and A156.19. Unit shall meet C-UL US.
Additional Detailed Specifications
When
activated, the unit shall, by means of an integral motor and chain
drive, power open the door at both a speed and force that are adjustable
to meet accessibility codes. The door shall be powered from a door
closed position to a full door open position and remain in momentary
hold open for ___seconds (adjustable 0 to 30 seconds) [(Unit shall power
open door to full open position up to 180° (5710); 170° (5730),
conditions permitting.) (Unit shall be capable of allowing the door
to be opened manually from 0 to 180°, conditions permitting.)] Once unit
reaches full hold open position, if reinitiated, unit’s momentary hold
open time shall restart from the initially set hold open time. If unit
is initiated during the closing cycle, unit shall revert to opening
cycle beginning at that door position. Obstruction detection on open
shall neutralize and reverse motor action reverting motor to closed
position thus allowing door to close under closer spring force only.
This obstruction detection feature shall be integral to unit. During
closing cycle, the unit shall close door under spring power not to
exceed a closing force of 15 lbf.
5710 Norton Door Operator Low Energy Pull Side mounting
- Brand: Norton
- Product Code: 5710
-
$2,617.62