• 677F319 Corbin Russwin Controller

*Actual product and finish may vary

Power Supply/Controller for ELR devices

Features

-2 control inputs. Accepts normally closed dry contacts for device activation from a key switch, push button, access

control or fire alarm system.

-2 normally open control outputs for automatic door operators

-2 M94 device outputs

-Fire Alarm Interface input

-12VDC output for audible or LEDS .25 AMP

-24VDC output for audible or LEDS .25 AMP

Wiring

-Up to 40 feet: 16 AWG wire.  Up to 60 feet: 14 AWG wire.  Up to 100 feet: 12 AWG wire.

Electrical Specifications

-120VAC 60 Hz Power input

-9 Amp inrush for 100 milliseconds

-Holding voltage @ 28volts unregulated

Listings

-Listed as an Exit Device Control Unit to UL 294 requirements.  Note: The 781N is the only power source to be used with the M94 option. Using any other power supply will void the warranty and cause possible damage to the exit device.

Ordering

-781N Controller

EPTL

-Concealed power transfer for over 120° swing doors. Installs in door and frame edges. Supports wires up to .25” (6mm) thick, and works with doors hung with butt hinges, continuous hinges and pivots.  To order, specify Part No. 704F28.