*Actual product and finish may vary
RCI AS65LMKM Latch Monitor/Keeper Monitor (Status) Heavy Duty Electric Strike without Faceplate for Hollow Metal and Wood Frame use with Cylindrical 3/4" Latch Projection-Centerline Mortise-Mortise Exit Device
RCI's "all-in-one" 6 Series electric strike combines several requested key features. Standard features include a multi-voltage single solenoid, selectable lock mode (no tools necessary), horizontal adjustment, and plug-in wire connectors. An optional monitor switch is also available.
LMKM - The Latch Monitor is a SPDT switch with a trigger located in the strike cavity to indicate the presence of a latch bolt when the door is closed. The Keeper Monitor is a SPDT switch that will indicate when the keeper moves from the closed (normal) position to the open position.
NOTE: LMKM Switches are rated at 2 Amps @ 24VDC
STANDARD FEATURES
Field selectable lock mode - choose fail locked or fail unlocked with the turn of a dial (Fail unlocked mode requires DC voltage)
Field selectable voltage input - accommodates 12 or 24VDC and 12 to 24VAC (even 16VAC) in one strike
UL Listed for 1500 lbs static strength
Dimensions: 1-1/4"W x 4-7/8"H
1/4" Horizontal Adjustment
Modular "plug-in" wire connectors for fast hook-up
Modular faceplate designs for a variety of frame types and cut outs
Frame Depth 1-3/16"
Faceplate Not Included
Non-Handed
US Patents 7,144,053 and 6,874,830
OPTIONS:
LMKM.......Latch Monitor/Keeper Monitor (Status)
LMKM - The Latch Monitor is a SPDT switch with a trigger located in the strike cavity to indicate the presence of a latch bolt when the door is closed. The Keeper Monitor is a SPDT switch that will indicate when the keeper moves from the closed (normal) position to the open position.
NOTE: LMKM Switches are rated at 2 Amps @ 24VDC
Selectable Voltages
Voltage Duty Sound Amps Ohms
12 VDC Continuous Silent .375 Amps 37 Ohms
24 VDC Continuous Silent .190 Amps 148 Ohms
12-24 VAC Intermittent Buzz .280 - .565 Amps 37 Ohms
Intermittent Duty = Energized less than 1 min. with Duty Ratio 1:5
Continuous Duty = Energized 1 min. or more
* Ratings are based on maximum current draw at +10°C and include initial power-up current draw.
† Nominal resistance at +25°C ± 7% tolerance
WARRANTY:
3 Year Limited Warranty
Certification:
UL 1034 burglary resistant Listed
UL Listed for 1500 lbs static strength (Tested on 04, and 14 faceplates only)
Factory tested to over 1,000,000 cycles of operation